Exide

Exide Batmobile Exide Care

Products

Exide Invaplus

HomeProductsExide Invaplus

Features of Exide Invaplus Range of Batteries

  • Inverter Battery - Exide Invaplus Very low maintenance: Special hybrid alloy system
  • High reliability and extended cycle life: Ribbed free polyethylene pocket type separator along with texturised glass mat - double-clad separation protects the design against internal short.
  • Thickplate construction with special paste formulation.
  • Hybrid alloy system for withstanding high ambient operating conditions as prevalent in India.
  • Easy maintenance: Float/Float Guide to indicate electrolyte level. Bolted type terminals fitted with shroud for easy connection
  • Instant state-of-charge indication: Magic Eye enables instant state-of-charge indication without having to open the plugs
  • Clean top with no surface leakage and fumes: Side vented designfitted with micro porous filter disc
  • Ready for commissioning: Factory-charged

Buy Automotive BatteryExide Batteries Product Catalogue


Application Chart for Exide Invaplus Range of Batteries

Electrical Load (with respect
to Max. Inverter Rating)
Max Inverter
Rating
System Voltage Recommended Battery for Different Back-Up Time
5 Hours. 3 Hours. 2 Hours.
1 Fan + 2 Tube lights 250VA 12V IP1350 IP880 IP650
1 Fan + 3 Tube lights 300VA 12V IP1500 IP880 IP880
2 Fans + 2 Tube lights 350VA 12V IP1500 IP1000 IP880
2 Fans + 3 Tube lights 400VA 12V IP2000 IP1500 IP1000
3 Fans + 3 Tube lights 600VA 12V - IP1800 IP1350
4 Fans + 4 Tube lights 800VA 12V - IP2000 IP1500
4 Fans + 5 Tube lights 850VA 12V - - IP1800
5 Fans + 5 Tube lights 900VA 12V - - IP1800
5 Fans + 6 Tube lights 1000VA 12V - - IP2000
6 Fans + 6 Tube lights 1200VA 24V - 2S-IP1800 2S-IP1350
8 Fans + 8 Tube lights 1600VA 24V - 2S-IP2000 2S-IP1500
8 Fans + 10 Tube lights 1700VA 24V - - 2S-IP1800
10 Fans + 10 Tube lights 1800VA 24V - - 2S-IP1800
10 Fans + 12 Tube lights 2000VA 24V - - 2S-IP2000

Note:
1. Cut-off voltage of inverter should be 10.5V (minimum). Tube light is considered as 40W & Ceiling Fan as (size 48") 70W.
2. There should be a periodic Bench-Charging of the battery after every three months from the date of installation.
3. 2S = Two batteries connected in series.

 

Technical Specifications of Exide Invaplus Range of Batteries

BATTERY TYPE PART NUMBER REF C20
CAPACITY
(AH)
MAXIMUM OVERALL DIMENSIONS NOMINAL
FILLED
WEIGHT (KG)
ELECTROLYTE
VOLUME (LITRES)
CHARGING
CURRENT (A)
ACID
LEVEL
INDICATOR
BATTERY
LAYOUT
      L
(MM)
W
(MM)
H
(MM)
H (With Float) (MM)          
IP650 FIP0-IP650 60 260 173 225 276 18.9 4.6 4.2 Present Right Layout
IP880 FIP0-IP880 88 410 176 233 279 26.6 6.8 6.2 Present Left Layout
IP1000 FIP0-IP1000 100 410 176 233 279 28.0 6.3 7.0 Present Left Layout
IP1350 FIP0-IP1350 135 508 222 257 281 40.5 10.9 9.5 Present Right Layout
IP1500 FIP0-IP1500 150 508 222 257 281 41.9 10.4 10.5 Present Right Layout
IP1800 FIP0-IP1800 180 521 278 270 289 55.2 15.9 12.6 Present Right Layout
IP2000 FIP0-IP2000 200 521 278 270 289 56.9 15.5 14.0 Present Right Layout